Certified design according to ANSI Z21.13 - CSA 4.9-2017 standards for indoor residential applications
Hot Water Flow Rate Capacity (* based on 67F temperature rise): CCOCB80155A - 4.0 GPM, CCOCB100180A - 4.7 GPM, CCOCB120199A/CCOCB140199A - 5.2 GPM
Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability
Weight - 95lbs
Stainless steel Flat Plate Heat Exchanger for DHW
Domestic Hot Water Priority
Compatible with 2" PVC vent up to 60ft** and 3" PVC vent up to 150 ft** (**with no elbows)
Built-in Control Panel - allows adjustment of temperature and boiler functions including Outdoor Reset Curve setting, heating setback, Integrated Low Water Safety Control, water fill pressure, and output capacity
Internal Circulation Pump - comes included with a primary circulation pump and air vent for added value and convenience
Temperature Options - two boiler setpoints: hydronic heating temperature setting range from 82F up to 180F and from 86F to 140F for DHW temperatures
Outdoor Reset Sensor - when installed with an Combi model, the unit controls will sense outdoor ambient temperatures and adjust the boiler operation for maximum comfort and efficiency